Product Navigation
Unique ductile iron groove housing improves overall performance
Patented square tail cover to control the screw rotation
Absolute mechanical synchronous lifting system
Safety nut design monitors the wear condition of the product and eliminates hidden dangers
Combined with reduction motors and various accessory modules to meet any customer requirements Thrust range: 500 kg - 100 tons
Screw jack parameters
Note: Ambient operating temperature for all series of products: -10℃-40℃, (If -40℃-+70℃ is required, please consult local engineers)
The lead screw can provide double-ended and triple-ended lead screws, and the lifting speed increases proportionally. Please consult the sales engineer for specific parameters.
Selection considerations:
◆The duty cycle is the percentage of working time within 10 minutes. The duty cycle of SJA series ordinary gear screw jacks is 30%, and the duty cycle of ball screw screw jacks is 50%. When the actual load is less than the rated load, the duty cycle can be appropriately increased. Please consult an engineer for details.
◆Maximum input speed is 1800rpm
◆When the actual load is 25% to 100% of the full load (i.e. the load rate is 25%-100%), the input torque = load rate x full load torque
◆When the stroke is greater than 300mm, the stability should be checked. Please refer to the load and stroke stability curve for verification.
◆Adjust the safety factor according to the load type. Uniform load 1.0-1.2; Medium load 1.3-1.5; Heavy load 1.6-2.5
◆The input power of the screw jack under normal working conditions cannot exceed the maximum input power, input power kW = (full load torque Nmx load rate x input speed rpm) / 9550
◆The working environment temperature affects the maximum input power.
Actual maximum input power = rated maximum input power x temperature coefficient, -10℃-25℃ temperature coefficient = 1, 30℃ temperature coefficient = 0.85, 40℃ temperature coefficient = 0.65
◆The combination coefficient should be considered when designing a synchronous lifting platform, and the linkage loss should be considered when calculating the total power. The combination coefficient of two units is -0.95; three units is -0.9; four units is -0.85; 6-8 units is -0.8. When the spiral lift is hinged at both ends, the combination coefficient should be appropriately increased.
◆Ordinary gear screw screw jacks with large reduction ratios have a self-locking function, while those with small reduction ratios have uncertain self-locking. Brakes must be configured in safety and vibration situations.
◆The lead error of ordinary toothed screw and ball screw lifts over a 300mm travel is 0.1mm.
◆ To avoid lateral force on the screw jack, you can consider using guide rails, guide devices, etc. to offset the lateral force or use a self-aligning nut screw jack.
◆For non-standard special design requirements, please contact our engineers.