Product Navigation
Model Selection
1. Calculation formula for model selection: (1)PIN=P1Xf(Starts and stops per hour ≤20 times/hour)
(2)PIN=1.2XP1Xf(Starts and stops per hour 21~60 times/hour)
(1)PIN≤PN
The selected power must be less than or equal to the allowable power
Where: PIN is the selection power, P1 is the actual required power, f is the service factor, PN is the allowable power.
Service factor f
Thermal power verification
1. Thermal power calculation: PGN=PGXf1×f2
PGN>P1(Natural cooling)
PGN Where: f1 is the ambient temperature coefficient, f2 is the continuous operation coefficient, PG is the heat capacity of the reducer, P1 is the actual required working power, PGN is the calculated heat capacity of the reducer. 2. Ambient temperature coefficient f1 3. Continuous operation coefficient f2 Heat capacity PG(Natural cooling) General technical specifications 1. Key and keyway dimensions comply with GB1095-79 and GB1096-79 standards, keyway width tolerance: shaft N9, hub JS9. 2. Output and input shaft center holes are generally threaded, specifications as follows: D=11~13mm Thread M3 D>24~30mm Thread M10 >13~16mm Thread M5 >30~38mm Thread M12 >16~21mm Thread M6 >38~50mm Thread M16 >21~24mm Thread M8 >50~85mm Thread M20 3. In the outline installation dimension drawing, the input and output shafts, under allowable speed and torque conditions, may allow the output shaft to function as an input shaft for speed-increasing transmission.